Portable Patient Monitor 5100

#1060

Introduction
The 5100 patient monitor is a multi-functional test instrument that can be used for adults, for children and newborns. The user can select different measurement parameters according to different needs. The patient monitor can monitor NIBP, SpO2 and PR. It integrates the parameter measurement and display function into a compact, lightweight patient monitor that is suitable for all levels of hospitals, medical and home use.

Features
1) is applicable for monitoring NIBP and SpO2 adults, pediatric and newborns of all ages, easy to operate, high efficiency;
2) applicable to medicine, surgery, operating room, ICU / CCU, ambulance, obstetrics and gynecology, pediatrics;
3) compact and flexible appearance, easy to carry and suitable for indoor and outdoor (ambulance) monitoring;
4) Built-in lithium polymer battery, providing continuous monitoring;
5) Perfect menu design, user-friendly interface;
6) Displaying the measurement results of SYS, DIA, MAP, SpO2, PR and histograms on the high-brightness screen of the digital tube;
7) 2.8 '' (320 × 240) full-color TFT LCD screen, displays time information, SpO2 plethysmogram, alarm status, trend chart, list and system settings, etc .;
8) visual and audible alarm for SYS, DIA, MAP, SpO2 and PR, as well as the upper and lower limit of the alarm can be set as needed;
9) independent energy-resistant memory, storage of up to 2000 NIBP data groups and 78000 SpO2 data groups;
10) convenient and quick review of measurement data, available for viewing the NIBP trend trend 24 hours and the SpO2 trend trend 22 hours.

Performance
1 monitoring system
Using oscillometric technology, also called oscillographic technology for measuring blood pressure.
1) Measurement mode: manual / automatic / continuous
2) measurement interval in the automatic mode: 1, 2, 3, 4, 5, 5 × n (n = 2, 3, 4 ... 51) Min.
3) Resolution: 1 mmHg. Art.
4) Accuracy: maximum average error: ± 5 mm Hg. v .; Maximum Standard Deviation: 8 mmHg. Art.
5) Overpressure protection: double protection for software and hardware
6) Others: reset, self-test and accuracy of static pressure testing
7) Measuring range:

For adults
SYS 40 mm PT ~ 270 mm RT
Map 20 mm Hg ~ 235 mm RT
Diameter 10 mm Hg ~ 215 mm Hg
Defibrillator (Andes):
SYS 40 mm PT ~ 200 mm PT
Map 20 mm Hg ~ 165 mm Hg
Diameter 10 mm Hg ~ 150 mm Hg
Newborn:
SYS 40 mm PT ~ 135 mm RT
Map 20 mm Hg ~ 110 mm Hg
Diameter 10 mm Hg ~ 100 mm Hg
2 SpO2
Using oxyhemoglobin photoelectric inspection technology in combination with pulse scanning technology and power recording to measure oxygen saturation in the blood.
1) Measuring range: 0% ~ 100%
2) Signal range: 0% ~ 100%
3) Resolution 1%
4) Accuracy: 70% ~ 100%, ± 2%; below 70% is not specified.
3 pr
Using oxyhemoglobin photoelectric inspection technology in conjunction with pulse scanning technology and recording power to measure heart rate.
1) Measuring range: 25 bpm ~ 250 bpm
2) Alarm range: 25 bpm ~ 250 bpm
3) Resolution: 1 bpm
4) Accuracy: ± 2 bpm or ± 2%, whichever is greater
4 Safety and power supply
1) Power supply: Rated voltage: ~ 220 V, Rated power: 50 Hz
2) Safety classification: class I equipment, type BF defibrillation-proof applied part

Accessories
1) User's Manual 1 pc.
2) power cord 1 pc.
3) power adapter 1 pc.
4) SpO2 sensor 1 pc.
5) NIBP cuff for adults 1 pc.
6) NIBP Extension 1 pc.

physical characteristics
Size: 190 mm (D) × 162 mm (W) × 240 mm (H)
Weight: 1.6 kg