Computed tomography CT
#1107
Node heat storage capacity: 3.5 MHU
Innovative anti-scatter mesh (ASG)
ASIC digital chip
Aperture : 70 cm
Digital tilt: ± 30 °
Manual Control with POD on Console
Portal cooling: air
Distance from focal spot to center ISO: 595mm
Portal rotation: belt driven
Minimum scan time: 0.75 s / 360 °
Slip Ring Type: Low Voltage
Positioning system: 3D lasers
Generator HV: Rated power: 32KW
Maximum weight load : 450 lb (205 kg)
Operating System: Windows 10 English
Console memory: 32 GB
High Definition Liquid Crystal Display: 24 '', 1920 x 1200
Low dose scanning 70 kV
Image processing with a large 1024 x 1024 matrix
3D volumetric VR reconstruction
Multi-plane MPR reconstruction
Curved Planar Reformatted CPR
Surface Shaded Display, SSD
Maximum intensity projection MIP
Minimum Intensity Projection MinP
Remote service system
Items |
|
1 |
Gantry |
1.1 |
Integrated Casting Gantry |
1.2 |
High – Precision Bearings |
1.3 |
Mobile Operation Panel |
1.4 |
Thermal Airflow Isolation Design |
1.5 |
Intelligent Temperature Control System |
1.6 |
Double Feedback Motion Control System |
1.7 |
Respiratory Navigation System |
1.8 |
Anti-Collision Safety Protection |
2 |
Tube |
|
|
3 |
Detector |
3.1 |
High-Precision And High-Strength Design |
3.2 |
Modularized Digital Detector |
3.3 |
Innovative Anti-Scatter Grid (ASG) |
3.4 |
Digital ASIC Chip |
4 |
HV Generator |
|
|
5 |
Table |
|
|
6 |
Console |
|
|
7 |
Scan And Image Reconstruction |
8 |
Built-in PDU |
|
|
9 |
Advanced System Software |
9.1 |
IMA Intelligent MA Modulation |
9.2 |
NDI Iterative Reconstruction |
9.3 |
MAS Metal Artifact Suppression |
9.4 |
Beam Hardening Artifact Correction |
9.5 |
Posterior Cranial Fossa Image Optimization |
9.6 |
Streak Artifact Suppression |
9.7 |
Helix Artifact Correction |
9.8 |
70KV low-dose Scanning |
9.9 |
1024 x 1024 Large Matrix Imaging |
9.10 |
Bolus Automatic Tracking |
10 |
AI Function |
10.1 |
Smart Puncture Positioning |
10.2 |
Smart Chest Reverse Scan |
10.3 |
STM Automatic MPR |
11 |
Clinical Application |
11.1 |
3D Volume Reconstruction VR |
11.2 |
Multi-Plane Reconstruction MPR |
11.3 |
Curved Planar Reformat CPR |
11.4 |
Surface Shaded Display SSD |
11.5 |
Maximum Intensity Projection MIP |
11.6 |
Minimum Intensity Projection MinP |
12 |
Remote Maintenance System |
13 |
UPS |
|
|
14 |
Accessory KIT |
|
|
1.3 |
Mobile Operation Panel |
|
table including fast and slow speed modes. |
1.4 |
Thermal Airflow Isolation Design |
|
degradation of the image quality. |
1.5 |
Intelligent Temperature Control System |
|
|
1.6 |
Double Feedback Motion Control System |
|
|
1,7 |
Respiratory Navigation System |
|
|
1.8 |
Anti-Collision Safety Protection |
|
|
2 |
Tube |
|
|
3 |
Detector |
|
|
3.1 |
High-precision And High-Strength Design |
|
|
3.2 |
Modularized Digital Detector |
|
number of X-ray photons. |
3.3 |
Innovative Anti-Scatter Grid (ASG) |
|
|
3.4 |
Digital ASIC Chip |
|
|
|
|
4 |
HV Generator |
|
· KV range: 70kV, 80kV, 100kV, 110kV, 120kV, 140kV |
5 |
Table |
|
|
6 |
Console |
|
|
|
|
7 |
Scan And Image Reconstruction |
|
|
|
|
8 |
Built-in PDU |
|
|
9 |
Advanced System Software |
9.1 |
IMA Intelligent MA Modulation |
9.2 |
NDI Iterative Reconstruction |
9.3 |
MAS Metal Artifact Suppression |
9.4 |
Beam hardening artifact correction software |
9.5 |
Posterior Cranial Fossa Image Optimization |
9.6 |
Streak Artifact Suppression |
9.7 |
Helix Artifact Correction |
9.8 |
70KV low-dose Scanning |
9.9 |
1024 x 1024 Large Matrix Imaging |
9.10 |
Bolus Automatic Tracking |
10 |
AI Function |
10.1 |
Smart Puncture Positioning |
10.2 |
Smart Chest Reverse Scan |
10.3 |
STM Automatic MPR |
11 |
Clinical Application |
11.1 |
3D Volume Reconstruction VR |
11.2 |
Multi-Plane Reconstruction MPR |
11.3 |
Curved Planar Reformat CPR |
11.4 |
Surface Shaded Display , SSD |
11.5 |
Maximum Intensity Projection MIP |
11.6 |
Minimum Intensity projection MinP |
12 |
Remote Maintenance System |
|
|
13 |
UPS |
|
|
14 |
Accessory KIT |
|
|
Top Sellers